        Gold-life micropump development and production center

        Homepage
        Favorite

        | Center introduction| Product Introduction | Applied Communication |  Services  | Contact|

        Select micro-pump

        pressure unit conversion table

        GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb

        Name and model

        Voltage

        (V)

        No-load Current

        (mA)

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        (mL/min)

        Weight

        (g)

        Pump Size

        Detailed Structure of the show

        reference Appearance

        GminiPA-1

        3.5

        30-50

        35

        -25

        800

        16

        162431

        >>here

        GminiPA-2

        3.5

        30-40

        35

        -20

        300

        16

        162431

        >>here

        Ibid

        pressure unit conversion table

        GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

        Name and model

        Voltage

        (V)

        No-load Current

        (mA)

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        (mL/min)

        Weight

        (g)

        Pump Size

        Installation instructions

        Detailed Structure of the show

        reference Appearance

        GminiPB-1

        3.5

        100

        35

        -25

        800

        28

        162441

        >>here

        GminiPB-2

        3.5

        100

        35

        -20

        300

        28

        162441

        >>here

        Ibid

        GMPA Series of micro-Pump  the pump size is small, current, power consumption, low noise, stable and reliable, with mounting holes for the lithium battery-powered instrument for the pursuit of high-quality user ,With special needs can be put on a positive pressure above 0.1mpa Suction pump for pocket analyzer, gas sampler, medical instrument, beauty instrument and so on.

        Name and model

        Voltage

        (V)

        No-load Current

        (mA)

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        (L/min)

        Weight

        (g)

        Pump Size

        Installation instructions

        Structure of the show

        reference Figure

        GMPA-1

        1.5-5

        test:4V

        40-100

        50

        20-30

        0.3-1.5

        35

        402336

        flow-load diagram

        voltage-flow chart

        Structure>>here

        GMPA-2

        2.0-5

        test:4V

        30-100

        50

        30-40

        0.5-2.0

        35

        402336

        Ibid

        Ibid

        GMPA-3

        3-6

        40-70

        50

        20-30

        0.5-1.5

        35

        402336

        Ibid

        Ibid

        GMPA-4

        3-6

        50-90

        50

        30-40

        0.5-1.8

        35

        402336

        Ibid

        Ibid

        GMPC Series of micro-pump   the pump size is small, low noise, small power consumption,stable and reliable hand-held devices used to pump suction. particularly suitable for demanding vacuum environments. with special needs can be put on a positive pressure above 0.1mpa .suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

        Name and model

        Voltage

        (V)

        No-load Current

        (mA)

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        (L/min)

        Weight

        (g)

        Pump Size

        Installation instructions

        Structure of the show

        reference Figure

        GMPC-1/2/3

        6/9/12

        <200/120/90

        >100

        50-65

        2.5-3

        45

        502231

        Structure>>here

        flow-load diagram

        voltage-flow chart

        GMPC-4/5/6

        6/9/12

        <150/110/80

        >80

        50-55

        2.0-2.5

        45

        502231 ibid

        ibid

        GMPD Series of micro-pumpsuction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump with special needs can be put on a positive pressure above 0.1mpa .

        Name and model

        Voltage

        (V)

        No-load Current

        (mA)

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        (L/min)

        Weight

        (g)

        Pump Size

        Installation instructions

        Structure of the show

        reference Figure

        GMPD-1/2/3

        6/12/24

        <230/130/80

        60-100

        60

        3-8

        82

        3544.556.5

        flow-load diagram

        voltage-flow chart

        Structure>>here

        GMPD-4/5/6

        6/12/24

        <200/100/60

        60-100

        50

        3-7

        82

        3544.556.5 ibid

        ibid

        Custom products 6,9,12,24 volts, flow 2L, 3l, 4l can be customized, there are 20 models

        GMPE Series of micro-pump To provide a special and long life motor, flow rate no less, suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

        Name and model

        Voltage

        (V)

        No-load Current

        mA

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GMPE-1/2

        12/24

        <180/90

        60

        50-55

        3-6

        149

        33543.572

        flow-load diagram

        voltage-flow chart

        Structure>>here

        GMPE-3/4/-

        12/24 -20-40 Custom 3L4L5L 149 3543.572

        Note: The custom products 2L, 3L, 4L can be customized, a total of 10 variety

        GMPF Series of micro-pump   A single-channel pump, flow is very stable, suitable for a variety of gas sampling.

        Name and model

        Voltage

        (V)

        No-load Current

        A

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GMPF25-1/2

        12/24 0.6/.3 >100 -70 25 480 8656.5126

        Structure>>here

        GMPF15-3/4

        12/24 0.6/0.3 >60 -50 18 480 8656.5126

        Structure>>here

        GMPG Series of micro-pump A new single-channel pump, flow is very stable, suitable for a variety of gas sampling, changes in motor and voltage can produce six varieties.

        Name and model

        Voltage

        (V)

        No-load Current

        A

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GMPG-1/2

        6-12/24

        <0.450

        100

        20-50

        36

        620

        8670126

        Structure>>here

        GMPG-3/4

        6-9/24

        <0.550

        100

        20-50

        36

        620

        8670126

        ibid

        GDMPB Series Mini Double Pump        The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

        Name and model

        Voltage

        (V)

        No-load Current

        A

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GDMPB-1/2

        6/12

        <0.25/0.135

        100

        series260

        -45-55

        series vacum

         -85

        single:22

        dual:2.8

        55

        244749

        flow-load diagram

        voltage-flow chart

        Structure>>here

        GDMPB-3/4

        6/12

        <0.25/0.135

        100

        series260

        50-65

        single:2.52

        dual:3.8

        55

        244749

        ibid

        GDMPC Series Mini Double Pump   The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

        Name and model

        Voltage

        (V)

        No-load Current

        A

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GDMPC-1/2

        12/24

        <0.135/0.08

        100

        series260

        -45-55

        series vacum

        -75

        single

        22L/min

        dual

        2.8L/min

        75

        244751

        flow-load diagram

        voltage-flow chart

        Structure>>here

        GDMPC-3/4

        12/24

        <0.135/0.08

        series

        260

        -50-65

        series vacum

        -80

        single:2.52

        dual:3.8

        5

        244751

        ibid

        GDMPD Series Mini Double Pump  The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit cost, function more flexible.

        Name and model

        Voltage

        (V)

        No-load Current

        mA

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GDMPD-1/2

        12/24

        <200

        /135

        100

        -40-50

        series vacum

        -75

        single:72

        dual:10

        107

        354855.5

        GDMPD-3/4

        12/24

        <240

        /135

        100

        -40-60

        series vacum

        -80

        single:82

        dual:11

        107

        354855.5

        GDMPD-5/6

        12/24

        <180

        /115

        100

        -35-45

        single:52

        dual:8

        107

        354855.5

        GDMPE Series Mini Double Pump The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit costs, function more flexible and longer motor life

        Name and model

        Voltage

        (V)

        No-load Current

        mA

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GDMPE-1/2

        12/24

        <180/100

        100

        -40-50

        series vacum

        -75

        single:62

        dual:10

        175

        354871.5

        flow-load diagram

        voltage-flow chart

        Structure>>here

        GDMPF Series Mini Double Pump  Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, micro-organisms, a variety of gas sampling. gas line more stable.

        Name and model

        Voltage

        (V)

        No-load Current

        A

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GDMPF(40)-1/2

        12/24

        0.80

        100

        20-60

        single:282

        dual:40

        618

        1056.5126

        voltage-flow chart

        Structure>>here

        GDMPF(25)-3/4

        12/24

        0.70

        100

        20-60

        single:202,

        dual:25

        663

        1056.5126

        ibid

        GDMPG Series Mini Double Pumpuse of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, sampling of the double-headed just need a pump

        Name and model

        Voltage

        (V)

        No-load Current

        A

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GDMPG(50)-1/2

        6-12/24

        <1.0

        60

        20-50

        single:352

        dual:50

        759

        11070126

        Structure>>here

        GDMPG(35)-3/4

        6-12/24

        <1.0

        -50-60

        20-50

        single:252

        dual:50

        759

        11070126

        Structure>>here

        GFMPE Series of four-channel Pump Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, can be composed of a four-way mixed-constant pump, flow is very stable.

        Name and model

        Voltage

        (V)

        No-load Current

        A

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        GFMPE-1/2 12/24 <0.67/0.35 -- 60 Four:5-18 375 4564.5124

        Structure>>here

        GFMPE-3/4

        12/24

        <0.67/0.35.67

        --

        45

        Four:3-15

        375 4564.5124
        Other Four:1-10 375 4564.5124

        HLA-2 Manual vacuum sampler series Test tube-specific, non-electric manual, negative pressure changes with the personal power

        Name and model

        Voltage

        (V)

        No-load Current

        mA

        Pressure

        (kPa)

        Vacum

        (kPa)

        Intake Flow

        L/min

        Weight(g)

        Pump Size

        Structure of the show

        reference Figure

        HLA-2

        --

        50mL and 100mL two tranches.

        Help

        Categories

         

                                   Return Home Page